Fire Sprinkler Coverage Diameter

Fire sprinkler system the world s most specified non metallic life safety piping system.
Fire sprinkler coverage diameter. The first step is to calculate the minimum flow which will be required at the most remote sprinkler which in this case is at node 130 this is a two step process as will need to calculate the minimum flow required to satisfy the 7 50 mm min design density and then find the flow rate from the sprinkler given the sprinklers minimum pressure requirement whichever is the greater flow will. Most fire sprinklers are available in two primary sizes. Ordinary hazard 100 square feet 9 3 sq m per. And may limit the amount of water required to supply extended coverage sprinklers.
The area watered by each sprinkler must overlap substantially the area watered by the adjacent sprinkler. 1 2 12 7 mm and 3 4 19 3 mm. Fire sprinklers are extensively used worldwide with over 40 million sprinkler heads fitted each year. Maximum coverage standard spray coverage is up to.
Extended coverage sprinklers have a water distribution radius of a little over 10 feet so they can be spaced approximately 20 feet apart. 5mm bulbs are used for standard response sprinklers 3mm bulbs are used for quick response sprinklers and 2 5mm bulbs are used for esfr s and fixed temperature release pilot line detectors pld. In these cases extended coverage sprinkler heads can be installed to increase the spacing between heads. There are two main criteria for determining the location of sprinkler heads.
In some circumstances standard distribution sprinkler heads will not provide enough coverage. Because fire sprinklers are heat activated sprinkler heads must be located high up on or near the ceiling. The different size bulbs relate to the response time index rti of the sprinkler. This means they cannot be blocked.
Light hazard 196 square feet 18 2 sq m. Sprinkler head location and coverage. In buildings protected by properly designed and maintained fire sprinklers over 99. This requires more sprinkler heads more pipe and more cost.
This measure determines the type of sprinkler response. Nominal thread size npt 15mm orfice size 13mm max. Sprinkler heads must be unobstructed to provide maximum flow to the areas that need it. This is important read it carefully.
Rising temperatures cause the alloy to melt allowing the metal elements to fall from the sprinkler head and activate the sprinkler. The requirements of 8 6 2 1 1 do not apply to small rooms as defined by 3 3 22. A fire sprinkler or sprinkler head is the component of a fire sprinkler system that discharges water when the effects of a fire have been detected such as when a predetermined temperature has been exceeded. Because this is light hazard you can apply nfpa 13 8 6 2 1 2 which states.
Without this overlap it would be impossible to design sprinkler systems that provided uniform water continue reading sprinkler coverage nozzle. Sprinkler is designed for standard or recessed installation. Copper tube size sdr 9 dimensions has a small inside diameter. Most effective in controlling the fire.