Dryer Exhaust Vent Location

Place a 4 1 2 inch stainless steel band worm gear hose clamp over the dryer s discharge vent.
Dryer exhaust vent location. Clean old ducts before installing the dryer. Step 3 remove the foam shipping pads see section 1. Step 5 connect the power supply see section 2. Clothes dryer exhaust venting faqs dryer vent questions answers troubleshooting safety repairs.
Duct and subtract 5 ft. This also means that you can t blow the dryer exhaust into the attic or the crawlspace. The route should be as short as possible but there are other guidelines to follow when venting a dryer. Vent distances terminations location routing draft boosters lint filters fire safety vent booster fans vent length diameter materials cleaning and other dryer vent.
Most traditional dryers have an exhaust opening on back side of the dryer s housing. A correctly installed dryer vent keeps your home safe by removing mois. Step 4 move the dryer to the desired location. The shorter the distance and fewer the turns the better for dryer vent installation.
You will note that it would not work for a regular floor level clothes dryer because there is insufficient width to collect the exhaust hose in the wall. The installation to the right is for a pedestal dryer. Move the dryer into position sliding the offset dryer vent connection over the dryer s discharge vent. Dryer vent installation can be a bit of a challenge.
Step 2 check and ensure the existing external exhaust is clean see section 1 and meets attached installation speciļ¬cations see section 3. Keep in mind these rules of thumb. The ductwork recommended for use between the dryer in the wall should be rigid or semi rigid modeled ducting that is 4 inches in diameter. Check your manufacturer s instructions on how to install a dryer vent for longer distances.
Do not use plastic or thin foil ducting. Proper dryer vent installation is vital to prevent fire and water damage to your home. Accordingly many homes have a dryer vent exhaust opening cut through the wall directly behind where a dryer. The length of the run should be no more than 25 feet.
Use no more than 25 ft. Models 350 and 425 install cleaner mid wall take up less cell space between the studs and allow for a more direct exhaust hose connection. You must terminate your dryer vent outside the building according to section m1502 of the irc. The first step of installing a dryer vent in a new location is to map out a path for the ductwork.
The exhaust duct run should be as short as possible. Step 6 connect the external exhaust see section 4. Make sure here is a good snug fit then move the band clamp over the duct connectors and tighten using a screwdriver or socket driver.